Honeywell Protectorelay® R8184M1051/U Oil Burner Control With Transformer, 120/240 VAC, 3.7 to 7.4 A, Intermittent Ignition, Domestic

HONR8184M1051 MFG #: R8184M1051/U
  • Amperage Rating: 3.7 to 7.4 A
  • Domestic / Import: Domestic
  • Ignition Type: Intermittent
  • Voltage Rating: 120/240 VAC
  • Dimensions: 4-3/8 in H x 4 1/8 in W x 2 1/2 in D
  • Manufacturer: Honeywell
  • Manufacturer #: R8184M1051/U
  • Mounting Type: Junction Box
  • Temperature Rating: -40 to 130 degF
The TRADELINE intermittent ignition oil primary control operates the oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat from the thermostat. Through a C554 Cad Cell Flame Sensor, the R8184 monitors the burner flame and shuts down the system on ignition failure or on flame failure during the run cycle. A light emitting diode (LED) on the terminal strip lights when the safety switch opens to provide safety shutdown indication. A manual reset button is provided to reset the safety switch after lockout. For convenience in system maintenance, the safety switch can be manually opened using a lever on the front of the control. Clock thermostats that power the clock through the primary control transformer will lose time during lockout unless backup batteries are installed.

Protectorelay® Oil Burner Control, 120/240 VAC, 3.7 to 7.4 A, Intermittent Ignition, -40 to 130 deg F, Junction Box Mount, 4-3/8 in H x 4 1/8 in W x 2 1/2 in D, Domestic
  • Features
  • Operates the oil burner and oil valves (if desired) in response to a call for heat from a low voltage control circuit
  • Intermittent ignition is on while the burner is on
  • Solid state flame sensing circuit
  • External button to manually reset safety switch after lockout
  • Enclosed safety switch must be manually reset after safety shutdown
  • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
  • Mounts on standard 4 x 4 in junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • 22.2 to 44.4 A at 120 to 240 VAC for locked rotor