1220 Economy Thermostat, Non-Programmable Thermostat, 45 to 90 Degree F Control

BRB1220 MFG #: 1220
  • Control Range: 45 to 90 deg F
  • Differential: 0.5 to 2 deg F Stage-1, 2 to 6 deg F Stage-2
  • Domestic / Import: Import
  • Terminal Designations: Rh, Rc, O/B, C, Y1, Y2, E/W1, G, W2
  • Thermostat Type: Non-Programmable
  • Dimensions: 3.7 x 5.16 x 1.38 in
  • Display Type: 3 sq-in Bright Blue Back-Lit
  • Fan Switching: Circulating
  • Humidity Range: 5 to 95 %
  • Manufacturer: Braeburn Systems
  • Manufacturer #: 1220
  • Number of Stages: 4
  • Power Source: Battery/Hardwired
  • Series: Economy
  • Stages Cool: 2
  • Stages Heat: 2
  • Voltage Rating: 24 VAC
The digital non-programmable thermostat shall be a Braeburn®, model number 1220, 3.70 in H x 5.16 in W x 1.38 in D, powered independently with either 24 VAC or two "AA" Alkaline batteries (3.0 Volt DC). The thermostat shall be compatible with multi-stage conventional systems with up to two stages of heating and two stages of cooling, heat pump systems with one compressor and up to one auxiliary stage. The thermostat shall have a bright blue backlight display, adjustable temperature limits, and separate sub-base for trouble free installation. Temperature control range shall be between 45 deg and 90 deg F, accuracy of +/- 1 deg F, humidity range between 5% and 95% relative humidity. The thermostat shall include non-volatile memory to retain user settings and auxiliary heat indicator. Thermostat shall have low battery indication and a front reset button will return user settings to default values when pressed. The thermostat can be mounted to a horizontal junction box.

Braeburn® Thermostat, Series: Economy, Non-Programmable Thermostat, 45 to 90 deg F Control Range, 0.5 to 2 deg F Stage-1, 2 to 6 deg F Stage-2 Differential, Terminal Designations: Rh, Rc, O/B, C, Y1, Y2, E/W1, G, W2, Fan Switching: Circulating, 4 Stage, 2 Stages Heat, 2 Stages Cool, 5 to 95 % Humidity, 3 sq-in Bright Blue Back-Lit, 24 VDC, Battery/Hardwired, 3.7 x 5.16 x 1.38 in, Import
  • Features
  • Includes
  • Adjustable temperature limits
  • Permanent memory retains settings
  • Compressor short cycle protection
  • Separate O and B terminals
  • Low battery indication
  • ESD Guard™ electronic circuitry
  • Front access reset button
  • Auxiliary heat indicator
  • Mount to horizontal box
  • +/- 1 deg F accuracy
  • 14 to 140 deg F storage temperature
  • Up to 2 heat/1 cool conventional
  • Up to 2 heat/1 cool heat pump
  • Compatible with conventional systems up to two stages of heating and one stage of cooling, heat pump systems with one compressor and up to one auxiliary stage, 250 to 750 mV heating systems
  • Deg F/C switch
  • 0.5, 1 and 2 deg F stage 1
  • 2, 3, 4, 5 and 6 deg F stage 2
(2) AA Alkaline Batteries