CentriPro® Aquavar® SPD Plus™ SPD20200F Variable Speed Standard Drive Simplex Pump Controller With Filter

GOUSPD20200F MFG #: SPD20200F
  • Amperage Rating: 60.6 A
  • Suitable For Use With: 20 hp Submersible and Centrifugal Pump
  • Voltage Rating: 208 / 230 V
  • Manufacturer: Xylem
  • Manufacturer #: SPD20200F
  • Phase: 1 or 3
  • Type: Variable Speed Standard Drive
A variable speed pump controller made specifically for single pump booster applications. Comes complete with pressure transducer and standard NEMA 3R outdoor rated enclosure.

CentriPro® Aquavar® SPD Plus™ Simplex Pump Controller, Variable Speed Standard Drive, 208/230 V, 1 or 3 ph, -22 to 122 deg F Ambient, 60.6 A, For Use With: 20 hp Submersible and Centrifugal Pump
  • Features
  • Easy set-up pre-set for surface motor characteristics, pre-wired and tested transducer
  • Pre-wired and tested transducer
  • Touch button pressure setting
  • No complicated menus or electrical jargon to cope with
  • Total set up time including wiring is less than 30 min
  • Dual phase the same drive can be used for either three phase or single phase input (de-rated)
  • Transducer with all goulds water technology drives, the pressure transducer is included with the drive so there is no need for separate sourcing and compatibility checks
  • The transducer is pre-wired and tested, with internal case grounding
  • Full diagnostics, in addition to typical electrical protection and diagnostics, the S-Drive has a full range of pump protection features such as bound pump or motor shut down, low water or loss of prime shut down
  • These added features require no added input devices
  • Program security, flashing LED status indicator will not fade in outdoor use the way LCD screens do, and the internal single push button discourages tampering by untrained operating or maintenance personnel
  • Remote on/off permits external control by timers (irrigation), float or pressure switches (tank draining) or manual control
  • Reduces the need for separate patch panels
  • Remote monitoring external monitors may be connected to the drive for pump running speed (Hz), pump on and system fault
  • The fault indicator can also be connected to devices like an auto-dialer
  • This enables control of pumps and drives in un-manned locations
  • Dual set point the S-drive has the capability to be programmed with two pressure set points
  • An external contact such as a timer can be used to change between them, so that a booster pump serving both a building and an irrigation system can do both jobs without manual resets
  • Dual phase